Tablet punches and dies supplier in China: Clean room (aseptic room) daily management: establish a safety and health duty system, once found ventilation system, walls, ceilings, floors, doors, windows and public media systems and other facilities have damage, to report in time and take appropriate repair measures, and keep records in a timely manner. Clean rooms, also known as sterile environments or hygienic facilities, are critical components in industries such as pharmaceuticals, electronics, and microelectronics. These controlled environments ensure that the products being manufactured are free from contaminants, pollutants, and other unwanted substances that could compromise their quality or safety. To maintain the highest standards of cleanliness and hygiene in these environments, organizations often adhere to specific international standards known as the ISO (International Organization for Standardization) code. In this blog post, we will explore what the ISO code for clean rooms is and how it can be used to evaluate and improve a facility’s cleanliness. See even more info on cleanroom pharma.
The mask making machine is used to manufacture various masks with certain filtering performance by hot pressing, folding and forming, ultrasonic welding, waste cutting, ear belt and nose beam welding and other processes of multi-layer non-woven fabrics. The mask production equipment is not a single machine, but requires the cooperation of multiple machines to complete various processes. The popular mask equipment in the market include: cup type mask machine, non-woven flat mask machine, N95 mask machine, 3m9001/9002 folding mask machine, duck mouth type mask machine, three-dimensional dust-proof mask machine, etc.
Pharmaceutical equipment includes: granulating oven, boiling dryer, wet machine, pulverizer, vibrating screen, slicer, drug frying machine, drug frying machine, tablet press, pill making machine, multi-functional extraction tank, liquid storage tank, liquid distribution tank, decompression drying oven, tilting reaction pot, capsule filling machine, bubble type packaging machine, particle packaging machine, powder packaging machine, V-type mixer, lifting feeder, etc.
Use a Hygrometer: A hygrometer is a device that measures the current humidity level in the room. By regularly monitoring the cleanroom humidity control with a hygrometer, you can identify any fluctuations and take corrective action if necessary. Ventilation: Proper ventilation is crucial for maintaining healthy humidity levels in clean rooms. Ensure that there are sufficient exhaust fans in place to remove excess moisture and carbon dioxide from the air. Additionally, consider installing temperature and humidity sensors to monitor changes in the environment and adjust ventilation accordingly. Control Water Sources: Closely monitor water sources within the clean room, such as sinks or taps, as they can contribute to high humidity levels. Be sure to turn off faucets when not in use and avoid running water unnecessarily.
Cleanroom workshop take the control of inanimate particles as the object. Mainly control the pollution of the living objects with living particles to the outside situation and people. The negative pressure inside the atmosphere must be maintained. it’s suitable for bacteriology, biology, clean laboratory, physical engineering, recombinant genes, vaccine preparation. In order to know your requirement, please fill the following table carefully and supply CAD layout, so that we can provide correct scheme and quotation, thank you!
The detection of air volume and wind speed must be carried out first, and all effects of purified air conditioning must be obtained under the designed air volume and wind speed. Before air volume detection, it is necessary to check whether the fan operates normally, whether all components in the system are installed correctly and whether there are obstacles (such as whether the filter is blocked or blocked). All valves should be fixed at a certain opening position, and the size of the measured air outlet and air duct must be measured. For the turbulent flow clean room, the air supply volume shall be determined by the air outlet method or air duct method. See Item 6, 7 and 8 respectively. For the air outlet without filter, the method in Appendix I of the current national standard code for construction and acceptance of ventilation and air conditioning engineering (gbj243) can be implemented.
Airflow is the most important factor in controlling cleanliness and temperature and humidity, and it also has some influence on noise. Therefore, the wind speed measurement is the first step in the clean room test. The purpose of the wind speed measurement is to confirm that the air flow sent by the filter meets the design specifications, and the second is to confirm the uniformity of the air flow. In some occasions, due to site restrictions, the indoor ventilation volume must also be converted by multiplying the wind speed by the outlet area. See even more information at https://www.sz-pharma.com/.
Tablet punches and dies factory today: Obstacles such as work desks in the clean room will have eddy currents at the junctions, and the cleanliness will be relatively poor near them. Drilling air return holes on the work desks will minimize eddy currents; assembly Whether the selection of materials is appropriate and whether the equipment layout is perfect are also important factors for whether the airflow becomes a vortex phenomenon. The above introduction is related to clean room and airflow influencing factors.
The clean room is generally made of foam color steel or rock wool board with a vertical wall and an independent air-conditioning air supply system. The air is filtered through high-efficiency three-stage filtration in junior high schools. The personnel and materials are equipped with an air shower room and a transfer window for clean filtration.