Interesting Things Blog Energy Core slitting machine supplier factory from China

Core slitting machine supplier factory from China

Dry type electrical transformers manufacturer factory today: Adjustment under heavy load or short circuit conditions is not allowed: Under heavy load or short circuit conditions on the transformer, tap changer adjustment may cause arcing or excessive current, resulting in damage to the tap changer or transformer. Obey the operating procedures and safety measures: When operating the on-load pressure regulating device, you need to abide by the operating procedures and safety measures, such as wearing protective equipment and following the operating procedures to ensure safe operation. In summary, it is not allowed to operate under live conditions, frequent adjustments, heavy loads or adjustments under short-circuit conditions. When operating the on-load pressure regulating device, the operating procedures and safety measures should be followed to ensure safe and stable operation. Find extra information at dry type transformer manufacturers.

What is eddy current? What are the disadvantages of eddy current generation? Eddy current refers to a kind of current generated in the conductor, which is the induced current caused by the change of the magnetic field. The eddy current forms a circular current flow path in the conductor, and this current forms a motion state similar to an eddy current inside the conductor, so it is called an eddy current. The generation of eddy currents has the following disadvantages: Energy loss: Eddy currents create circular currents in conductors, which generate heat as they flow continuously in conductors. Since the generation of eddy currents is caused by changes in the magnetic field, in equipment such as transformers and motors.

When these harmonic currents flow through a transformer, they can cause increased core losses due to hysteresis and eddy currents. Hysteresis loss is related to the magnetization and demagnetization of the transformer’s core material in response to the alternating current. Eddy current loss occurs when induced currents circulate within the core material, creating local magnetic fields that oppose the main field. Both these losses increase with the frequency of the current. Thus, higher frequency harmonic currents can lead to considerably higher core losses, reducing the transformer’s efficiency and causing it to overheat, which can shorten its lifespan.

Canwin, a electrical equipment manufacturer mainly produces 150 model oil-type transformer core shearing equipment below 1 600KVA, 300 model dry type transformer core shearing equipment below 6300KVA, 400 model special transformer core shearing equipment below 12500KVA and 600 model special transformer core shearing equipment below 63000KVA. 800 model extra transformer core shearing equipment, 1000 model extra transformer core shearing equipment, the type 1250 model CRGsilicon steel CNC slitting machine, and the dry type transformer core under 110KV automatic cutting and laminated processing center, oil transformer core automatic cutting robot automatic lamination processing center, reactor cutting center below 35Kv, 220KV high voltage china transformer equipment tc. Transformer core & transformer coil manufacturing and assembly, including coil windings using copper and silver alloyed or continuously transposed copper cable.Canwin hire famous designer in Europe as our senior consultant, and germany Siemens as our strategic partner. The products have formed 5 series and more than 50 specifications.Canwin is your best choice of electrical equipment suppliers.

CANWIN is not just a length lines company, but also electrical equipment manufacturer. It is the legend of people who have forged their lives with faith and action. CANWIN electrical machinery equipment manufacturing deploys an innovation chain through the industrial chain.Equipment sales can provide integrated solutions; can provide OEM/ODM services to global transformer manufacturers; can provide raw material supply to transformer manufacturers. In the form of cooperation and mutual benefit, set up the transformer manufacturing center and core processing base in the Middle East, India. Dubai. Vietnam. Thailand. etc.

Three-dimensional wound core transformer breaks through the traditional triangle plane structure, adopts three-phase symmetric vertical structure, magnetic circuit completely symmetrical three-phase core products, magnetic resistance is greatly reduced, excitation current, no-load loss, is a kind of using traditional materials, but lower operating noise, structure is more compact and efficient energy-saving oil type transformer. Its excellent performance in energy saving and energy saving and environmental protection is in line with China’s energy conservation policy.

A transformer coil winding machine is an intricate piece of machinery with an essential role in the manufacturing of transformers, combining modern technology and meticulousness to create high-quality products efficiently. The process starts with the feeding of copper wire into the machine, which passes through a line-up of calibrations guides and tensioners designed to secure alignment and prevent damage. An automated system then causes rotation, gradually looping copper wire around the transformer coil. A computerized system oversees variables such as speed, pitch control, layer count and insulation thickness for consistent turns. Moreover, for distinct transformer models or designs, these machines can be fitted with extra features such as automatic lead cutting and tapping mechanisms for increased versatility and productivity.

The manufacturing technology and product quality of electrical steel plate is one of the important signs to measure the development level of special steel production and science and technology in a country. At present, the quantity, quality and specification of cold rolled electrical steel in China cannot meet the needs of energy (power) industry development, and there is a big gap between China and Japan in terms of production technology, equipment, management and scientific research.Canwin is one of the most professional silicon steel sheet suppliers in China, which has been specialized in silicon steel manufacturing for over 20 years.Contact us, we are the best choice. See extra details on https://www.canwindg.com/

Epoxy resin is non – combustible, flame retardant, self – extinguishing solid insulation material, safe and clean. It is also a solid insulation material with proven insulation and heat dissipation technology for more than 40 years.Epoxy resin products can be used for dry type transformer, for insulation parts, for instrument transformer, for electrical composite parts and for room temperature curing. Epoxy resin dry transformer uses epoxy resin as insulation material. The high and low voltage windings are made of copper tape (foil), industrial epoxy resin is poured in vacuum and cured, forming a high strength FRP body structure. Insulation grade F, H. Epoxy resin dry transformer has the characteristics of good electrical performance, strong resistance to lightning impact, strong resistance to short circuit, small size and light weight. Temperature display controller can be installed to display and control the operating temperature of the transformer winding to ensure the normal service life of the transformer.

The main pillar of the smart grid is the smart substation, which is not only an important hub for power transmission and distribution, but also directly affects the operational and monitoring capabilities of the smart grid through its operational safety and stability. Through the network, information can be exchanged, and the transformer can share information with the process layer and the station control layer. On the premise of ensuring product performance, the integration of monitoring, control, measurement, protection, and metering is designed to achieve the integration of transformer components with actuators, sensors, and transformers.

Connection group label: According to the phase relationship between the primary and secondary windings of the transformer, the transformer windings are connected into various combinations, which are called the connection group of the windings. In order to distinguish different connection groups, the clock notation is often used, that is, the phasor of the line voltage on the high-voltage side is used as the long hand of the clock, fixed at 12, and the phasor of the line voltage on the low-voltage side is used as the short hand of the clock. The number of the short hand indicates the connection group label. For example, Dyn11 indicates that the primary winding is (triangle) connected, and the secondary winding is (star) connected with a center point, and the group number is (11) points.